| Laboratory Capabilities
Based on our current laboratory instrumentation, we have the ability to perform the following measurements.
Other capabilities exist with our consortium members.
Please contact us for specific details.
- Diffusion Coefficient Measurement
|
| Isotropic |
Anisotropic |
| Nuclei |
H-1, C-13, P-31, N-14 |
H-1 |
H-1 |
| D |
10-4 to 10-8 cm2/s |
10-4 to 10-6 cm2/s |
10-4 to 10-8 cm2/s |
| Sample Size |
5 mm |
70 cm |
5 mm |
| Temperature |
-50 to 200 oC |
RT |
-50 to 200 oC |
- Imaging
| Field Strength (Bo) |
50 mT |
1.5 T |
3 T |
7 T |
11.7 T |
| Field of VIew (FOV) |
7 cm |
4 - 40 cm |
4 - 40 cm |
4.5 mm |
4.5 mm |
| Nuclei* |
H |
H |
H |
H |
H |
| Pixel Size |
120 μ |
80 μ |
80 μ |
20 μ |
20 μ |
| Sequences |
SE |
SE, Grad. Echo, FSE, IR, MRA, D, EPI |
SE, Grad. Echo, FSE, IR, MRA, D, EPI |
GE, SE, IR |
GE, IR |
* Other nuclei available on request.
- MRI and NMR Radio Frequency Coil Tuning
Tune NMR imaging or spectroscopy coil.
Frequency Range: 5 to 500 MHz
Impedance: 50 or 75 Ohms
- MRI and NMR Radio Frequency Coil Construction
Design and build a radio frequency RF coil for NMR imaging or spectroscopy in the 5 to 500 MHz range.
- High Resolution NMR Spectroscopy
| Field Strength (Bo)
| 7 T (300 MHz)
| 11.7 T (500 MHz) |
| Sample Size
| 5 mm |
5 mm |
| Nuclei* |
H-1, C-13, P-31, N-15 |
H-1, C-13, P-31, N-15 |
| Temperature |
-50 to 200 oC |
-150 to 150 oC |
| 1D and 2D Pulse Sequences |
Bruker Library |
Bruker Library |
| Phase |
Liquid |
Liquid |
* Others are available depending on sensitivity.
- Radio Frequency Magnetic Field Mapping
Map the transmit and receive radio frequency magnetic field distribution in an MRI coil.
Spatial resolution = 0.004 of largest coil dimension
Field resolution = 0.01 of largest field value
- Spin-Lattice Relaxation Time (T1) Measurement
Analysis: monoexponential, biexponential, multiexponential, and principal component
| Field Strength (Bo)
| 50 μT
| 1-18 mT*
| 0.75 T
| 1.5 T
| 7 T
| 11.7 T |
| Maximum* |
5 s |
5 s |
10 s |
3 s |
10 s |
10 s |
| Minimum* |
50 ms |
50 ms |
10 ms |
100 ms |
10 ms |
10 ms |
| Nuclei |
H |
H |
H |
H |
H + others |
H + others |
| Temperature |
RT |
RT |
RT |
5 to 50 oC |
-50 to 200 oC |
-150 to 150 oC |
| Analysis |
ROI |
ROI |
ROI |
ROI & Image |
ROI |
ROI |
* - Signal strength dependent
ROI - Region of Interest
- Spin-Spin Relaxation Time (T2) Measurement
Analysis: monoexponential, biexponential, multiexponential, and principal component
| Field Strength (Bo)
| 50 μT
| 0.75 T
| 1.5 T
| 7 T
| 11.7 T |
| Maximum* |
1 s |
1 s |
1 s |
1 s |
1 s |
| Minimum* |
35 ms |
1 ms |
10 ms |
1 ms |
1 ms |
| Nuclei |
H |
H |
H |
H + others |
H + others |
| Temperature |
RT |
RT |
5 to 50 oC |
-50 to 200 oC |
-150 to 150 oC |
| Analysis |
ROI |
ROI |
ROI & Image |
ROI |
ROI |
* - Signal strength dependent
ROI - Region of Interest
- Dielectric Constant & Resistivity
Measure the relative dielectric constant and resistivity of liquids and gells.
Frequency Range = 100 kHz - 200 MHz
Minimum Sample Volume = 5 ml
- MRI Phantom Design and Prototyping
We specialize in custom engineered phantoms to meet specific QC imaging needs.
Some examples of our work include:
| Phantom |
Features |
|---|
| Relaxation Time |
Fixed T1 and T2 values. |
| Resolution |
Measure resolution and PSF in 3D without repositioning. |
| Diffusion |
Water based, selectable D values between DWater and 0.25 DWater. |
| fMRI |
Switchable T2 value. |
| Fat Sat |
Variable fat-to-water ratio solution for fat-saturation imaging. |
| Digital |
Determine segmentation accuracy. |
Go to: [
Home |
Services |
Capabilities |
Instruments |
Personnel |
Reports |
IP ]